Tychem® ThermoPro - Fabric Data |
Properties |
Test Method |
Results |
|
Basis Weight
|
 |
ASTM D 751
|
 |
8.12 oz/yd2
|
 |
|
Thickness
|
 |
ASTM D 1117
|
 |
34 mils
|
 |
|
Grab Tensile Strength
|
 |
ASTM D 751
|
 |
243 lbf MD/ 231 lbf CD
|
 |
|
Ball Burst
|
 |
ASTM D 751
|
 |
178 lbf
|
 |
|
Puncture Propagation Tear
|
 |
ASTM D 2582
|
 |
27.7 lbf MD / 27.9 lbf CD
|
 |
|
Puncture
|
 |
ASTM D 1342
|
 |
2509 g force
|
 |
|
Viral Barrier
|
 |
ASTM D 1671
|
 |
Pass
|
 |
|
Trapezoidal Tear
|
 |
ASTM D 5733
|
 |
51 lbf MD/ 34 lbf CD
|
 |
|
Cold Flex -25? C
|
 |
NFPA 1992, ?5.1.6
|
 |
0.097 in lb MD/CD
|
 |
|
TPP Contact
|
 |
NFPA 2112
|
 |
17.2 cal
|
 |
|
TPP Spaced
|
 |
NFPA 2112
|
 |
19.9 cal
|
 |
|
500?F Oven Shrinkage
|
 |
NFPA 2112
|
 |
8.1% MD / 7.8% CD
|
 |
|
12 Sec. Vertical Flammability per NFPA 2112
|
 |
Afterflame
|
 |
0 sec MD/CD
|
 |
|
12 Sec. Vertical Flammability per NFPA 2112
|
 |
Char Length
|
 |
1.2 in. MD/ 1.4 in. CD
|
 |
|
12 Sec. Vertical Flammability per NFPA 2112
|
 |
Drip
|
 |
No
|
 |
|
12 Sec. Vertical Flammability per NFPA 2112
|
 |
Melt
|
 |
No
|
 |
|
Flame Spread
|
 |
16 CFR 1610
|
 |
Class 1
|
 |
|
Seam Strength
|
 |
ASTM D751
|
 |
63.1 lbf / 2 in
|
 |
|
Closure Strength
|
 |
ASTM D751
|
 |
16.5 lbf / 2 in
|
 |
|